Detailed Product Description: vaginal electrode probe
Anal | Vaginal probe MSM-15
Maismed Instrument is a professional Chinese manufacturer of tens machine in In our domestic Chinese market and abroad market, our company has been manufacturing mainly the following products:
mainly Tens machine unit products:
Transcutaneous Electrical Nerve Stimulators (TENS machine unit)
Electrical Muscle Stimulators (EMS, NMS)
Interferential Stimulators (INF)
Micro Current Stimulators
Incontinence therapy devices
Products have Safety Approvals and Compliances such as FDA, CE / Medical, cMET, TGA, RoHs, REACH
PROBES INSERTABLE ELECTRODE
VAGINAL PROBE ELECTRODE
Specification
Materials:
Probe body: High Impact Polystyrene
Electrodes: Medical Grade Stainless Steel
Cables: PVC over copper tinsel conductors
Weight: 23.5g, Cable Length: 30cm
Connectors: 2 x 2mm diameter sockets
Electrode Surface Area: 3cm2 per electrode
‘In Use’ product lifetime: 6 months
Features:
- An extremely lightweight construction.
- Ergonomically designed for maximum comfort during use.
- Extra large conductive area to ensure maximum stimulation.
- Fully sealed unit to aid and simplify the cleaning and serialising procedure.
- 2mm dial universal socket and soft, flexible cable.
- Soft curved shape to assist insertion and comfort.
- Diameter at widest point: 80 mm long
- Connection: Connects to Tens leads with 2 pin connectors
- For vaginal / Vaginal use
- Ideal for Pelvic Floor Exercise
Indications for Use:
For use as an intra-anal probe in males and females and a small vaginal probe in females. For use only with muscle stimulation and EMG biofeedback equipment approved to EN60601-01 in the treatment of ‘Stress’, ‘Urge’ and ‘Mixed’ incontinence and faecal incontinence.
FOR SINGLE PATIENT USE – may be re-used by the same patient.
FOR SINGLE ORIFICE USE – not for both vaginal and anal use.
Use as directed by your medical adviser.
Contraindications & Precautions:
DO NOT USE:
With electrical stimulation if fitted with a cardiac pacemaker • If pregnant
• If the package seal is not intact • If an infection or tissue damage or recent surgical scar is present • Vaginally during menstruation • With electrical stimulation in patients with a history of carcinoma at the site of stimulation
• If an irritation or discomfort occurs and seek medical guidance.
CAUTION IS ADVISED:
When using electrical stimulation on patients with altered or reduced tissue sensation • During electrical stimulation if the user has a history of epilepsy – seek informed medical guidance • When using the ANUFORM® with equipment capable of delivering outputs in excess of 2mA/cm2. If in doubt contact the equipment manufacturer or your medical adviser.
Cleaning:
• Wash in warm soapy water.
• Rinse in clean water and dry.
• Repeat after each use and dry thoroughly before storing in its plastic bag.
• DO NOT use boiling water.
Disposal:
Clean thoroughly and dispose of according to local regulations.
Contains nickel:
May cause irritation or allergic reaction following prolonged contact.
Always follow the user instructions.
Indications for Use:
IMPORTANT:
• Before first and subsequent use wash and dry as directed.
• Apply light coating of KY Jelly or similar lubricating gel to tip and metal surfaces of probe to aid insertion and provide good electrode conductivity.
• Anal use: Insert into anus while ‘bearing down’ as if passing stool. ‘Ring’ part of probe should remain external to the anus at all times.
• Vaginal Use: Insert into vagina in an ‘East/West’ position, i.e. with the metal electrode surfaces facing towards the hips. Insert until body of probe
is within the vaginal vault. ‘Ring’ part of probe should remain externally within labia.
• Ensure equipment is turned off before connecting to probe cables.
• Use as directed by your medical adviser. After use, turn off equipment, disconnect cables. Do not pull on cables to remove probe.
• Wash, dry and store as instructed on previous page.
incontinence stimulation electrode position
Incontinence Stimulation Probe (Electrodes)
The Incontinence Stimulation Probe (Electrode) are intended to provide electromyography feedback from pelvic musculature or electrical stimulation to pelvic musculature for the purpose of rehabilitation of week pelvic floor muscles and restoration of neuromuscular control during the treatment of urinary incontinence.
Electrode orientation:
Model Maismed-01/02/11/12/14/15 of subject device provide the shell type of orientation,
Model Maismed-03/04/05/06/07/08/09/10/13 of subject device provide circular type of orientation.
The MaisMed Incontinence Stimulation Electrode models Maismed-01/02/03/04/05/06/07/08/09/10/11/12/13/14/15 are the light weight cylinder consisting of two or three independent conductive rings or plates that are paired and isolated, physically and electrically. The cylinder is shaped with a waist and handle for comfort positioning in vaginal canal for incontinent treatment and easy in removing after treatment. It is watertight to allow for washing with soap and water between uses.
A broad range of ECG monitoring solutions by Maismed
Electrocardiography is the process of recording the electrical activity of the heart over a period of time using electrodes placed on a patient’s body. These electrodes detect the tiny electrical changes on the skin that arise from the heart muscle depolarizing during each heartbeat.
MaisMed Instrument ECG products are designed for health care. Users obtain accurate records by simple operation, including:
• Desktop ECG 133 with 3 electrodes
• Handheld ECG 159 with 3 electrodes & Detector
Designed in accordance with best-in-class standards, MaisMed Instrument ECG measurements provide information for the care of patients in a wide range of care environments.
Measure Symptoms promptly:
– Unexpected Breathing
– Dizzy, Apnea, Easy to Tired
– Fatigable, Edema, Syncope
– Paroxysmal Cardiogram
– Out of Breath
MaisMed ECG measurement including as:
• Convenient switching between Skin-conductor and 3-lead electrodes (Handheld type only)
• Continuous ECG monitoring from only 3 electrodes or Skin-conductor
• ST segment analysis
• Simultaneous real-time display
• Up to 25 memories content 30 seconds for each record for Desktop type and 25 memories for Handheld type.
(A) Vaginal Probe Electrodes |
(1) Model: Maismed-02
Material: SUS & ABS
Diameter: Dia.28mm x 80mm (Length)
(2) Model:Maismed-02
Material: SUS & ABS
Diameter: Dia.28mm x 80mm (Length)
(3) Model: Maismed-03
Material: SUS & ABS
Diameter: Dia.28mm x 159mm (Length)
(4) Model: Maismed-04
Material: SUS & ABS
Diameter: Dia.25mm x 100mm (Length)
(5) Model: Maismed-05
Material: SUS & ABS
Diameter: Dia.25mm x 145mm (Length)
(6) Model: Maismed-06
Material: SUS & ABS
Diameter: Dia.25mm x 120mm (Length)
(7) Model: Maismed-07
Material: SUS & ABS
Diameter: Dia.20mm x 56mm (Length)
(B) Rectal Probe Electrodes |
(8) Model: Maismed-08
Material: SUS & ABS
Diameter: Dia.14mm x 85mm (Length)
(9) Model: Maismed-09
Material: SUS & ABS
Diameter: Dia.16mm x 103mm (Length)
(10) Model: Maismed-10
Material: SUS & ABS
Diameter: Dia.16mm x 103mm (Length)
(11) Model: Maismed-11
Material: SUS & ABS
Diameter: Dia.18mm x 88mm (Length)
(12) Model: Maismed-12
Material: SUS & ABS
Diameter: Dia.18mm x 129mm (Length)
(13) Model: Maismed-13
Material: SUS & ABS
Diameter: Dia.16mm x 64mm (Length)
(C) Vaginal & Rectal Probe Electrodes |
(14) Model: Maismed-14
Material: SUS & ABS
Diameter: Dia.34mm x 78mm (Length)
(15) Model:Maismed-15
Material: SUS & ABS
Diameter: Dia.16mm x 64mm (Length)
Specification:
For Vaginal Stimulation Electrodes:
Insert into vagina with electrode surfaces facing ‘East-West’ i.e. towards hips. Insert until body of Incontinence Stimulation Electrode is within the vaginal vault. ‘Ring’ part of the probe should remain external within labia.
Model | Probe Length (inches) |
Probe Diameter (inches) |
Electrode Spacing (inches) |
Active Surfaces, Area (inch2 / band) |
Maismed-01 | 2.7 | 0.994 | 0.55 | 0.63 |
Maismed-02 | 2.7 | 0.994 | 0.55 | 0.60 |
Maismed-03 | 6.3 | 1.102 | 0.59 | 1.23 |
Maismed-04 | 3.9 | 0.984 | 0.71 | 1.22 |
Maismed-05 | 5.7 | 0.984 | 0.20 | 1.22 |
Maismed-06 | 4.7 | 0.984 | 0.16 | 1.22 |
Maismed-07 | 2.2 | 0.787 | 0.87 | 0.97 |
Maismed-14 | 3.1 | 1.339 | 1.14 | 0.48 |
Maismed-15 | 3.4 | 0.945 | 0.63 | 0.37 |
For Anal Stimulation Electrodes:
Insert into ANUS whilst ‘bearing down’ as in passing stool. Anal sphincter should ‘lock’ around narrow neck of probe. ‘Ring’ part of probe should remain external to the anus at all times.
Model | Probe Length (inches) |
Probe Diameter (inches) |
Electrode Spacing (inches) |
Active Surfaces, Area (inch2 / band) |
Maismed-08 | 3.3 | 0.551 | 0.31 | 0.28 |
Maismed-09 | 4.1 | 0.630 | 0.12 | 0.48 |
Maismed-10 | 4.1 | 0.630 | 0.43 | 0.48 |
Maismed-11 | 3.5 | 0.709 | 0.12 | 1.31 |
Maismed-12 | 5.1 | 0.709 | 0.12 | 1.31 |
Maismed-13 | 2.5 | 0.315 | 0.24 | 0.25 |
Maismed-14 | 3.1 | 1.339 | 1.14 | 0.48 |
Maismed-15 | 3.4 | 0.945 | 0.63 | 0.37 |
Approvals :
Safety IEC60601-1:2005/GZME130700043001 AA00000
EMC EN60601-1-2:2007/GZME130700305001
CE Certificate: HK03/02005
FDA 510K/K161055
Standard Export Package: upright and beam will be packed in plastic films and bubbles to protect from abrasion;
Accessories will pack in cartons.
We consistently provide sincere and promot service:
– Before we and customers make a deal, we always offer lastest profiles, such as: project drawing, quotation sheet, customer data(tens is 9018909000 )
After we sign the contract and before our goods reach customers’ end, we offer: installation drawings, package photos, shipping documents…
For special & complex project, we could send engineer to customers’ site for development guide.
Please inform us the following information for a quick quotation:
1) layout of your tens machine
2) function requirement of the device
3) dimension and design of package
4) How many channels you want
5) How many sets of cargo you need to storage
About MaisMed tens units, China:
MaisMed Instrument Co., Ltd is found in 2005. It specializes in the development, design and production of home medical products and rehabilitation products in China, supply quality products at competitive prices. We would like to be your reliable supplier and trusted friends. Thank you for your attention!
We have became long-term suppliers for famous enterprises, such as: bytech, bio, Roscal and so on. You can refer to: https://www.maismedtens.com
May Li
MaisMed Instrument Co., Ltd
Address: #A2 Building 1,Biomedicine Innovations Industrial Park,China
E-mail: may@maismedtens.com admin@maismedtens.com
Mobile: +86 18128589153
Website: www.maismedtens.com
Skype:may_maismedtens
facebook: Li May
TENS Units | Chinese tens machines| Chinese tens machines manufacturer
Relative Keywords
medical equipment suppliers
pain relief electrical stimulation
You may also be interested in:
tens pads
welding electrodes
vaginal probe
electric stimulation machine
tens machine pads
tens device
tens machine for knee pain
anal probe
medical equipment sales
electrode potential
electro stimulation machine
electric stimulation therapy machine
Business Type:
where to buy tens machine
tens pain relief
pads for tens machine
medical device manufacturers
electrodes
medical equipment manufacturers